问题:单选题A customer plans to deploy Open Fabric Manager (OFM). Which vendors would you recommend?()A Brocade B Blade Network Technology (BNT) C Cisco D Juniper
查看答案
问题:单选题retail company plans to consolidate 180 existing dual processor Xeon servers, all running a web server application on Windows Server 2003. They are planning consolidating to a single x3950 X5 running vSphere.Which of the following should be discussed with this customer? ()A Is the web content static or dynamic information B Consider two servers for redundancy and failover C What is the average CPU utilization of the existing web servers D Will the servers need a SCSI or Fibre Channel storage solution
问题:单选题A banking customer has a firewall between their AMM and the remote console which is used to configure the chassis and blades. Due to security concerns, port 80 (http) is being blocked, denying any http access to the AMM. Which of the following would facilitate remote communication with the AMM using a GUI interface?()A port 443 - SSL connection B port 8080 ?http C port 22 - SSH CLI D port 427 - SLP connection
问题:单选题An eX5 client is concerned about the cost-per-GB of the proposed SAS disk-based solution, and suggests using SATA disk technology in order to reduce costs for their 24x7 mission-critical Microsoft SQL Server application. Which of the following addresses the customer issues?()A SAS drives support automatic rebuild upon failure, SATA must be rebuilt manually B SAS drives support Fibre Channel attachment to eX5 servers, SATA does not C SATA drives require different, more expensive cables, and require more floor space compared with SAS D SATA storage is slower, has lower mean time between failure, and designed for a lower duty cycle compared with SAS
问题:单选题A banking customer plans to implement a BladeCenter H chassis. They plan for seven HS22 blades, six HX5 blades with MAX5, one 1U external Fibre Channel switch, and two 3U Fibre Channel storage devices with fourteen 146GB drives. Which of the following is the minimum amount of rack space required to implement the solution?()A 32U B 25U C 22U D 21U
问题:单选题A prospect is considering a BladeCenter H chassis with the Multi-Switch Interconnect Modules. The number of Ethernet ports is important to them. What is the maximum number of Ethernet ports an HS22 blade server can support if the blade does not have any expansion blades attached?()A 8 B 6 C 4 D 2
问题:单选题A medical customer has an installed HS21 blade with no local disk. They are attempting to set up boot from SAN using a Windows 2003 CD. Which sequence is correct for this procedure? ()A Install Windows from the CD using the QLogic driver provided on the CD, configure the LUN and zone for the target server, and then configure the blade UEFI to boot from SAN.B Configure the LUN and zone for the target server, install Windows from the CD and press F6 when prompted to supply the driver, and then configure the QLogic adapter BIOS to boot from SAN. C Configure the LUN and zone for the target server, configure the QLogic adapter BIOS to boot from SAN, install Windows from the CD, and then press F6 when prompted to supply the driver. D Configure the blade UEFI to boot from SAN, configure the LUN and zone for the target server, and then install Windows from the CD using the QLogic driver provided on the CD
问题:单选题A customer has downloaded new firmware files for the IBM support Web Site. Which of the following is the correct method for updating the firmware for the QLogic Intelligent Passthru Module using the command line?()A Transfer the file to the FC module using FTP; use Telnet to the FC module to start the updateB Use Telnet to the AMM to transfer the file using TFTP; start the updateC Transfer the file to the FC module using Secure Copy Protocol (SCP);use Telnet to the FC module to start the updateD Start the update and enter FC module IP address when prompted
问题:单选题A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch.Which of the following should be mentioned to the customer regarding the NPIV switch?()A You can not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch B Using blade servers with the NPIV switch will require more fibre ports on the external fibre switch C Storage devices like Fibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switchD The NPIV switch will count against the number of domains in a fabric
问题:单选题A customer has a BladeCenter H chassis with a single AMM. The AMM is defective. Which of the following is the method to backup the existing AMM so the new AMM automaticlally picks up the configuration? ()A Back up the AMM configuration to a file B Back up the AMM configuration to the chassis C Back up the AMM using IBM Systems Director D Back up the AMM using Tivoli Storage Manager
问题:单选题A banking customer has two Ethernet Switch Modules installed in an IBM BCE chassis. The modules were configured identically. The Ethernet module in bay 1 was accidentally reset to factory defaults. Which solution returns the module to the customer-specific configuration? ()A Restore the configuration from NVRAM using the Switch Module Web interface B Back up the configuration of the Ethernet module in bay 1 and restore it to the Ethernet module in bay 2 using the AMM C Swap the modules, which will automatically resynch the settings stored in the Advanced Management Module D Back up the configuration from Ethernet module in bay 2 and restore it to the module in Bay 1 using the switch CLI or Web interface
问题:单选题A customer is concerned that the Windows server virtualization solution discussed with them seems to be too leading edge. They are not comfortable with new technology What information could be supplied to provide industry trends and directions of the solution?()A Server Proven B Client references C xREF D IBM White Papers
问题:单选题Which of the following steps does a customer use to upgrade the firmware on the AMM to the latest level?()A Open a Web browser and log on to the IMM; in the navigation frame, click IMM Firmware Update under IMM Control; click Browse; select the .exe file; click the Upgrade/Update button B TFTP to the AMM; from the Main Menu, select Update; browse to the downloaded .exe file C Telnet to AMM; from the Main Menu, select Update; browse to the downloaded .pkt file D Open a Web browser and log on to the AMM; in the navigation frame, click AMM Firmware Update under AMM Control; click Browse; select the .pkt file; click the Upgrade/Update button
问题:单选题In which phase should a TDA be performed?()A Server deployment B Installation and server configuration C Problem determination/resolution D Needs analysis and design
问题:单选题When selling against competition, which of the following focus on the iDataPlex value proposition? ()A Superior chip density B Balance performance, cost, and power+cooling efficiency C Flexible configurations ready for integration and testing at the customers data center D Standard rack mounting
问题:单选题A Customer has a proprietary server deployment solution that uses a combination of disk imaging and application pushing technology. They need to get a working Windows 2003 image for their new servers as soon as possible for deployment with their provisioning system. Which of the following methods can achieve this? ()A Install Windows 2003 using the F6 supply Mass Storage Controller option B Replace Customers deployment solution with Tivoli Provisioning Manager for OS Deployment Director Edition C Use ServerGuide to install Windows 2003 D Deploy Customers existing image and use UXSPi to update IBM specific drivers
问题:单选题A customer is looking at an Oracle eBusiness solution. They would like to know what hardware they will need for the solution. They have some preliminary information from Oracle, including hardware requirements and specifics for their environment. Which of the following should be done next?()A Configure a 2 node x3950 X5 B Customer needs a System p server to support Oracle applications C Download the Oracle eBusiness sizing questionnaire from IBM, fill out with customer and submit to IBM for System x sizing D Configure a system that meets the minimum requirements