Disable the ServRAID cache
Change the RAID level to 10
Change the cache level to Write Through
Add five more drives to the array to increase the number of read/write heads
第1题:
A customer has a requirement for a server to run Windows Server 2003 Enterprise Edition and Exchange 2003 Enterprise Edition. It has been determined that 4GB RAM will be needed. The customer is trying to decide between the two following configurations: (1)An IBM xSeries x366 with 4 Xeon MP processors and 4 x 1GB memory DIMMs. (2)An IBM xSeries x445 with 4 Xeon MP processors and 8 x 1GB memory DIMMs. Which question should be asked to guide the customer in selecting the correct memory configuration?()
第2题:
A healthcare customer has an IBM System i server and an HP-UX server. They have high performance I/O, image-based, and archival applications. The customer has asked the IBM team for guidance on IBM DS8000 disk technologies. Which DS8000 disk technology would provide the best performance without regard to cost to meet the customer requirement()
第3题:
Upon announcement,the specific details surrounding the Virtual I/O Server requirements and performance are still being defined. The customer has engaged IBM to provide a server consolidation solution and would like to take advantage of the VIO Server benefits. How should the pSeries technical specialist best address this?()
第4题:
A customer has an x445 and uses the internal LSI adapter to manage two 146GB drives in the chassis. The customer is noticing performance issues when deploying a database with significant write activity on the internal drives. Should they consider using a ServeRAID-6M with 256MB of cache instead, and why or why not?()
第5题:
An existing IBM customer has some iSeries servers in their environment. The customer is adding an x366 server with an RSA-II installed for their Microsoft Client/Server applications. The customer wants to consolidate the storage and centralize the backup of the iSeries and xSeries platforms. Which of the following will accomplish this?()
第6题:
An administrator recently installed a new array controller into a server. When the server is running POST the controller does not appear as present. Which of the following could be the reason for this?()
第7题:
An xSeries specialist monitors a customer’s server that has poor performance. The customer is running an x365 with a ServeRAID 6i controller with write-back cache turned on and ten 15K rpm drives in a RAID-5 array. It is a mission-critical server and must have a redundant storage system. Performance tests indicate that the Average Disk sec/Transfer exceeds 20 ms. Which of the following is the lowest-cost method to increase the throughput?()
第8题:
A customer is building a database server, and the server does sequential write most of the time. They are planning to use an IBM x445 and a ServeRAID-6M adapter. Which of the following fault tolerant RAID levels will perform best for sequential write?()
第9题:
A customer has a file server with RAID-5 using 8KB random I/Os, with 67% reads and 33% writes. How should the disk controller cache be configured for optimal performance?()
第10题:
A customer has a file server using RAID-5 with 8KB sequential write operations. How should the disk controller cache be configured for optimal performance and data integrity?()