Add or remove the resources in the profile, click 'apply', then 'save'.
Add or remove the resources using DLPAR and change the partition profile.
Add or remove the resources using DLPAR, then shutdown and reactivate the LPAR.
Add or remove the resources in the system profile and reboot the managed system.
第1题:
A client is experiencing issues after cloning an LPAR using alt_disk_install. DLPAR functions are not available for the new LPAR. Also, there is a lot of network traffic to the HMC. What is the most probable cause of this problem?()
第2题:
A user is reporting that a PC will suddenly shut down without warning. The PC boots up with no problems, but after using the PC for a short time, the PC turns off. Which of the following components should the technician check?() (Select TWO).
第3题:
A customer opened a ticket with the help desk two days ago to report that their computer ismaking a strange loud noise. Which of the following should the technician do FIRST after arriving at the site?()
A. Ask another technician who has worked with this computer previously to learn about any other prior issues.
B. Ask the customer open-ended questions to attempt to narrow down the issue, then repeat the issue to the customer for validation.
C. Ask the customer close-ended questions to attempt to narrow down the issue while not using technical jargon to avoid overwhelming the customer.
D. Run preliminary diagnostic tests to narrow down the issue and update the status of the trouble ticket then ask the customer about any changes they have made to the computer.
第4题:
A p5 570 customer is currently running AIX 5.3. The customer now wants to add Virtual Ethernet to two of the LPARs. This will enable the application tier can communicate to the database tier without using an external Ethernet card. What is the best way to accomplish this task?()
第5题:
A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system. How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()
第6题:
A customer has been receiving warning alerts on their storage units. All data is protected nightlyby a backup and has been tested without any issues. What should the customer do prior tocontacting IBM Support?()
第7题:
An administrator has shut down a server to install additional memory. When the administrator restarts the server after the upgrade, it times out. Which of the following could be the cause of the problem?()
第8题:
An administrator has shut down a server to install additional memory. When the administrator restarts the server after the upgrade, it times out. Which of the following could be the cause of the problem?()
A. Processor failure
B. Third party memory
C. Disk drive failure
D. ESD during the upgrade
E. Backplane failure
第9题:
A customer has an existing DS5300 system attached to two Brocade switches with eight Windowsservers. The customer wants to add their System i p750 server to this SAN. From the followingchoices what is the simplest and least expensive solution for this customer?()
第10题:
When doing the Solution Assurance for a p5 570 with several LPARs, it is discovered that the customer plans to back the system up using mksysb. The customer would like to do unattended automated system backups and incorporate them into their off-site data recovery system. Which mksysb solution should be implemented?()