单选题An IT director needs to deploy 3 partitions, each using dedicated internal boot disk. Which system will support the customer requirement using the least amount of rack space?()A Power 770 serversB Power 750 serversC Power 755 serversD Power 720 servers

题目
单选题
An IT director needs to deploy 3 partitions, each using dedicated internal boot disk. Which system will support the customer requirement using the least amount of rack space?()
A

Power 770 servers

B

Power 750 servers

C

Power 755 servers

D

Power 720 servers

参考答案和解析
正确答案: C
解析: 暂无解析
如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

A small IT department is deploying Power 720 servers exploiting virtualization technologies.  Each Power 720 will have two partitions, one with 6 cores and one with 2 cores, and both partitions having 32GB of memory each. Live Partition Mobility is being considered at some point in the future. What is the minimum AIX Edition required to support the customer?()

  • A、AIX Basic Edition
  • B、AIX Express Edition
  • C、AIX Standard Edition
  • D、AIX Enterprise Edition

正确答案:C

第2题:

An administrator has a single 14U rack.  The administrator needs to install fifteen servers; rack-mounted redundant uninterruptible power supplies (UPSs), a network switch, and a KVM.  Which of the following server types would be BEST suited for this scenario?()

  • A、Blade servers
  • B、Rackmount servers
  • C、Tower servers
  • D、Web servers

正确答案:A

第3题:

AnITdirectorneedstodeploy3partitions,eachusingdedicatedinternalbootdisk.Whichsystemwillsupportthecustomerrequirementusingtheleastamountofrackspace?()

A.Power770servers

B.Power750servers

C.Power755servers

D.Power720servers


参考答案:A

第4题:

A customer has a new Power 720 with PowerVM Standard Edition.  They plan to migrate their single-partition POWER5 550 to the new Power 720.   How can the customer migrate from the POWER5 550 to the Power 720 with minimal effort and down time?()

  • A、Perform Live Partition Mobility between the two systems.
  • B、Move the boot disks from the old system to the new system.
  • C、Use Tivoli Storage Manager to back up the POWER5 550 and restore on the Power 720.
  • D、Upgrade AIX to the latest level on the POWER5 550 and clone using the mksysb command.

正确答案:D

第5题:

A customer plans to consolidate several systems onto POWER7. Their immediate requirement is to have a single Power 770, and they will buy a second Power 770 at a later stage. They want to keep their existing three POWER5 570s and three POWER6 520s which are all managed by an HMC (7310-CR3). Which of these statements is true and would minimize the cost?()

  • A、All the machines can be connected to the existing HMC, as long as it is updated to code level 7.7.1 or later
  • B、The Power 770 requires an HMC (7042-CR5 or later), so they must buy one. All of the systems can be managed by this new HMC
  • C、They should buy a new HMC for the Power 770 system, and leave the POWER5 and POWER6 based  systems connected to the existing one
  • D、The Power 770 requires an HMC, so they should connect the Power 770 to the HMC and convert the POWER5 and POWER6 based servers to IVM

正确答案:A

第6题:

A customer has two Power 770 systems with 4 enclosures each.  Thirty two cores and 1TB of memory are activated on each system.  Each system has 3 database partitions and each partition has 10 cores and 300GB of memory.   Which solution will provide automated recovery of unplanned outages at least cost?()

  • A、Purchase PowerVM Enterprise Edition.Use System Director to automate Live Partition Mobility to recover from partition failure
  • B、Create additional shared processor partitions as standby nodes.Use PowerHA SystemMirror to activate and use CoD resources when a failover occurs
  • C、Purchase an additional 32-core Power 750 with PowerHA SystemMirror Standard Edition.Use the new system as standby node with the XD component of PowerHA
  • D、Purchase an additional Power 770 system.Locate production and standby database partitions on each system.Use DB2 pureScale to provide automated partition monitoring and failover

正确答案:B

第7题:

Which system provides the highest performance per core, and the least cost for applications licensed per core?()

  • A、A Power 795 with MaxCore mode
  • B、A Power 780 with MaxCore mode
  • C、A Power 755 with TurboCore mode
  • D、A Power 780 with TurboCore mode

正确答案:D

第8题:

A customer has a mixed environment of AIX on POWER4 and POWER5, and x86 based systems running a supported distribution of Linux. There is a total of 7 partitions and three standalone x86 servers. The customer wants to consolidate their applications using a single 4-core POWER6 server.  What is the minimum PowerVM edition that supports the customer requirement?()

  • A、 PowerVM Lx86
  • B、 PowerVM Express Edition
  • C、 PowerVM Standard Edition
  • D、 PowerVM Enterprise Edition

正确答案:C

第9题:

A customer has a key application running in a logical partition on a POWER5 system. The customer wants the ability to run the application with minimal down time using Live Partition Mobility.  Which of the following is the minimum PowerVM edition and hardware configuration that will support the customer requirement?()

  • A、 PowerVM Standard Edition on POWER6 hardware
  • B、 PowerVM Standard Edition with POWER5 hardware 
  • C、 PowerVM Enterprise Edition with POWER6 hardware
  • D、 PowerVM Enterprise Edition with POWER5 hardware

正确答案:C

第10题:

A customer has requested five rack mounted servers, and a rack. They want redundant power connections. Which of the following is required to meet these requirements?()

  • A、Redundant power supplies on the servers
  • B、Redundant PDUs in the rack
  • C、edundant power supplies in the servers and redundant PDUs in the rack
  • D、Redundant power supplies in the servers, redundant PDUs in the rack, and Active Energy Manager (AEM)

正确答案:C

更多相关问题