The saturation temperature of the refrigerant must be () tha

题目
单选题
The saturation temperature of the refrigerant must be () that required in the evaporator refrigerated space.
A

above

B

below

C

equal to

D

None of the above

如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

Sub-cooling is a method of reducing the temperature of the liquid refrigerant below its ______.

A.freezing point

B.floc point(浊点)

C.condensing temperature

D.compression temperature


正确答案:C

第2题:

单选题
When the temperature of the refrigerant flowing out from the condenser is below the condensing temperature, it is said to be ().
A

dry

B

wet

C

super-cooled

D

superheated


正确答案: C
解析: 暂无解析

第3题:

The temperature of the refrigerant in the evaporator coil depends mostly upon the ___.

A.refrigerant pressure in the evaporator

B.cooling water temperature to the condenser

C.heat load in the refrigerator compartment

D.solenoid valve in the liquid line


正确答案:A

第4题:

单选题
If a refrigeration compressor is running continuously without lowering the temperature in the refrigerated space, the trouble may be ().
A

a shortage of compressor oil

B

warm food in the refrigerator

C

excessive condenser cooling water

D

a shortage of refrigerant


正确答案: A
解析: 暂无解析

第5题:

单选题
An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().
A

restriction in refrigerant piping

B

air and non-condensable gases in the condenser

C

water in the refrigerant

D

flooding back of liquid refrigerant from the evaporator


正确答案: C
解析: 暂无解析

第6题:

Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause______.

A.carbon deposits on the compressor suction valves

B.the evaporator temperature to increase

C.rapid corrosion of the thermal expansion valve

D.no operating problems


正确答案:B

第7题:

单选题
When you adjust a thermostatic expansion valve, ().
A

refrigerant must be bled off the sensing line before adjustments are made

B

all refrigerant must be pumped into the receiver before adjustments are made

C

time must be allowed for conditions to stabilize in the evaporator before further adjustments are made

D

all refrigerant must be routed through the dehydrator while changing the superheat setting


正确答案: B
解析: 暂无解析

第8题:

If the superheat value of a thermostatic expansion valve is set too low, the _.

A.the suction line will be abnormally cold and liquid may slug back to the compressor

B.the suction line will be hot due to a reduced amount of refrigerant returning to the compressor

C.the temperature of the refrigerant within the condenser will remain the same

D.the temperature of the refrigerant passing through the sub-cooler will decrease


正确答案:A

第9题:

单选题
Water evaporates or steam condenses at the saturation temperature, which depends upon the pressure, the higher the pressure () the saturation temperature.
A

the more

B

the higher

C

the lower

D

the highest


正确答案: B
解析: 暂无解析

第10题:

单选题
In a vacuum distillation system, the case is the higher the pressure, ().
A

the saturation temperature is higher

B

the higher the saturation temperature

C

the higher is the saturation temperature

D

the saturation temperature is more high


正确答案: A
解析: 暂无解析