题目
单选题
If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().
A

system was overcharged with refrigerant

B

high pressure switch was improperly adjusted

C

expansion valve strainers were fouled

D

suction valves were leaking slightly

参考答案和解析
正确答案: B
解析: 暂无解析
如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

Low compressor head pressure in a refrigeration system can be caused by ___.

A.insufficient condenser cooling water

B.excessive condenser cooling water

C.air in the refrigeration system

D.excessive refrigerant in the system


正确答案:B

第2题:

If a refrigeration system were short of refrigerant, the condition would result in

A.continuous running of the compressor

B.high suction pressure

C.high discharge pressure

D.short cycling of the compressor on the water failure switch


正确答案:A

第3题:

If the refrigeration compressor crankcase is sweating, the cause may be due to

A.a shortage of refrigerant

B.the compressor running continuously

C.liquid refrigerant returning to the compressor

D.the compressor short cycling on the high pressure cutout


正确答案:C

第4题:

单选题
Low compressor head pressure in a refrigeration system can be caused by().
A

insufficient condenser cooling water

B

excessive condenser cooling water

C

air in the refrigeration system

D

excessive refrigerant in the system


正确答案: A
解析: 暂无解析

第5题:

The sensing line for the low pressure cutout switch to a refrigeration system is located ______.

A.in the chill box(冰箱)

B.before the receiver

C.on the suction side of the compressor

D.on the discharge side of the compressor


正确答案:C

第6题:

In the refrigeration system, a shortage of refrigerant is indicated by

A.the compressor short cycling on high pressure cut out switch

B.high suction pressure

C.high head pressure

D.bubbles in the sight glass


正确答案:D

第7题:

If the suction pressure at the refrigeration compressor is below normal, the cause can be

A.refrigerant overcharge

B.overfeeding by the expansion valve

C.a restricted suction strainer

D.due to short cycling of the compress


正确答案:C

第8题:

If a refrigeration compressor is short cycling on high head pressure, you should

A.purge the condenser if the waterside is dirty

B.check for proper water flow through the condenser

C.increase the high pressure cutout setting

D.reduce the cooling water flow


正确答案:B

第9题:

If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.

A.an excess of liquid refrigerant

B.the expansion valve overfeeding

C.a fouled compressor suction strainer

D.the compressor short cycling


正确答案:C

第10题:

单选题
An important consideration in selecting a lubricating oil for use in a refrigeration compressor is for the oil to ()
A

have a high viscosity index

B

mix readily with refrigerant

C

have a high freezing point

D

have a low pour point


正确答案: A
解析: 暂无解析