A Windows server has rebooted by itself several times.There are several functioning non-Windows servers in the same rack that are connected to the same uninterruptible power supply(UPS).Which of the following is the MOST likely cause of the reboots?()A、Th

题目

A Windows server has rebooted by itself several times.There are several functioning non-Windows servers in the same rack that are connected to the same uninterruptible power supply(UPS).Which of the following is the MOST likely cause of the reboots?()

  • A、The UPS is malfunctioning.
  • B、The user traffic to the server is too high.
  • C、A BSOD is occurring.
  • D、The non-Windows servers cannot be located on the same UPS as the Windows server.
如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

An administrator will replace five current servers. Which of the following is the MOST important to review before installing new servers?()

A. Verify uninterruptible power supply (UPS) load

B. Verify if server consumes 220V

C. Verify CPU load

D. Verify if server consumes 110V


参考答案:C

第2题:

A server has a single failed hard drive in an array that is accessed through a hot plug backplane to ease replacement of failed drives. After replacing the drive several times, each of the replacement drives failed to power up and rebuild as the failed drive.  Which of the following is the MOST likely cause of the failures?()

  • A、 The backplane has failed and needs to be replaced.
  • B、 The array must be disbanded and recreated from a backup source to recognize the replacement drive.
  • C、 There is a conflict with the optical drive on the server.
  • D、 The server power supply is failing and not providing enough power for all the drives.

正确答案:A

第3题:

There is a power outage and all servers are shut down properly by the uninterruptible power supply (UPS) software. When one of the servers starts up it displays a logical drive failed error. This server has two processors, 16GB of memory, and a RAID 5 array with 10 drives.Which of the following is the MOST likely cause?()

A. A failed RAID controller

B. Two failed processors

C. Two failed sticks of memory

D. Two failed drives


参考答案:A

第4题:

A technician has just installed a new power supply into a desktop computer and now the computer will not turn on. Which of the following is the MOST likely cause?()

  • A、The voltage selector switch on the power supply is set incorrectly.
  • B、The 3.3v power line is connected to the wrong input on the motherboard.
  • C、The new power supply voltage rating is too high.
  • D、The 12v power cord is installed incorrectly.

正确答案:A

第5题:

Which of the following is the MOST likely to cause a server power supply fan to fail but allows the power supply to still be functional?()

  • A、Dust
  • B、Power Surge
  • C、Excessive humidity
  • D、High temperatures

正确答案:A

第6题:

An administrator has a malfunctioning uninterruptible power supply (UPS). Which of the following is the MOST likely cause of the problem?()

A. Battery needs to be replaced

B. Light switch is turned off

C. Smart cable is disconnected

D. UPS needs a firmware update


参考答案:A

第7题:

An administrator has a single 14U rack.  The administrator needs to install fifteen servers; rack-mounted redundant uninterruptible power supplies (UPSs), a network switch, and a KVM.  Which of the following server types would be BEST suited for this scenario?()

  • A、Blade servers
  • B、Rackmount servers
  • C、Tower servers
  • D、Web servers

正确答案:A

第8题:

Which of the following is the MOST important physical consideration when deploying a new server?()

A. Humidity monitors, Biometrics, and fire suppression

B. Cooling, rack space, and power requirements

C. Service level agreements, uninterruptible power supply (UPS) deployment, and CCTV

D. Biometrics, fire suppression, and power requirements


参考答案:B

第9题:

Which of the following is the BEST case scenario for power fault tolerance within a server?()

  • A、 Redundant power supplies with one power supply connected and one power supply as a hot spare.
  • B、 Redundant power supplies with each connected to a separate power circuit.
  • C、 Redundant power supplies connected via a Y-cable.
  • D、 Redundant power supplies with each connected to the same power circuit.

正确答案:B

第10题:

Which of the following is MOST useful in HVAC planning? ()

  • A、 Uninterruptible Power Supply (UPS) load
  • B、 Humidity
  • C、 Amperage
  • D、 Voltage
  • E、 Temperature

正确答案:B,E