单选题A server has five hot pluggable SCSI disk drives in a RAID 5 array. The server OS crashed and the server will not boot. The administrator noticed that all of the disk drives have gone offline.  Which of the following components would MOST likely have c

题目
单选题
A server has five hot pluggable SCSI disk drives in a RAID 5 array. The server OS crashed and the server will not boot. The administrator noticed that all of the disk drives have gone offline.  Which of the following components would MOST likely have caused the problem?()
A

 Memory

B

 SCSI backplane

C

 SCSI drives

D

 Motherboard

参考答案和解析
正确答案: A
解析: 暂无解析
如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to a RAID controller. The system administrator has decided to configure all six drives in a RAID 5 array.How much usable disk space will this array have?()

A.288GB

B.360GB

C.432GB

D.728GB


参考答案:B

第2题:

An administrator is building a server that will run a data warehousing application.The server was ordered with eight 300GB drives.The application requires a dedicated storage location for the OS and one for critical files.The critical file storage needs fast access but must provide high redundancy.The OS requires 100GB and the file requires 950GB.Which of the following configurations will BEST suit the data warehouse needs?()

  • A、OS:3 Drives,RAID 1 with hot spare;Files:5 Drives,RAID 5 with hot spare
  • B、OS:2 Drives,RAID 1;Files:6 Drives,RAID 1
  • C、OS:2 Drives,RAID 0;Files:6 Drives,RAID 5
  • D、OS:2 Drives,RAID 1;Files:6 Drives,RAID 5 with hot spare

正确答案:D

第3题:

A server configured with RAID 5 has recently suffered from two simultaneous disk failures. Which of the following would be required to bring the server back to operational status?()

A. Break mirror array

B. Replace cache battery

C. Replace hot standby

D. Restore from back up

E. Replace defective hard drives


参考答案:D, E

第4题:

A server contains a 3 disk RAID 5 array. The red LED is illuminated on one of the drives. Which of the following should the server administrator perform?()

  • A、Replace the drive
  • B、Restore the drive from backup
  • C、Reboot the server
  • D、Reconfigure RAID 5 to RAID 10

正确答案:A

第5题:

A server configured with RAID 5 has recently suffered from two simultaneous disk failures. Which of the following would be required to bring the server back to operational status?()

  • A、Break mirror array
  • B、Replace cache battery
  • C、Replace hot standby
  • D、Restore from back up
  • E、Replace defective hard drives

正确答案:D,E

第6题:

A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to a RAID controller. The system’s administrator has decided to mirror two drives for the operating system. Which of the following is the maximum space the administrator will have remaining to use for data when using RAID 0?()

  • A、292GB
  • B、438GB
  • C、584GB
  • D、728GB

正确答案:C

第7题:

A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to RAID  controller. The system administrator has decided to configure all six drives in a RAID 5 array.  How much usable disk space will this array have?()

  • A、 288GB
  • B、 360GB
  • C、 432GB
  • D、 728GB

正确答案:B

第8题:

A server has five hot pluggable SCSI disk drives in a RAID 5 array. The server OS crashed and the server will not boot. The administrator noticed that all of the disk drives have gone offline.Which of the following components would MOST likely have caused the problem?()

A. Memory

B. SCSI backplane

C. SCSI drives

D. Motherboard


参考答案:C

第9题:

An administrator is installing Windows Server 2003 via CD on a new server with an SAS RAID array. When the administrator reaches the option to select the target installation drive, there are no drives listed. Which of the following is the FIRST thing the administrator should do?()

  • A、Restart the installation via WDS.
  • B、Shut down the server and check that all RAID drives are connected properly.
  • C、Restart the installation from CD and press F6 to install RAID drivers.
  • D、Go into the BIOS and set all RAID drives to compatibility mode

正确答案:C

第10题:

Which of the following offers the MOST redundancy for a system but is also very costly? ()

  • A、 RAID implementation
  • B、 Disk-to-disk replication
  • C、 Server-to-server clustering
  • D、 Hot site replication

正确答案:D

更多相关问题